国产精品拍拍拍久久久无广告._日韩国产小说图片_9堂在线观看国产成人_日韩无码一级精品精品一级_欧美国产成人精品二区芒果视频_国产成人无码aⅤ一区二区在线观看_国产欧美另类在线制服_黄色网站全裸无码_yy4080爱水果高清水果影院_男人好看的av在线网站

Jiangyin Shenpu New Material Technology Co.

Focus on hydrogen energy, fuel cell and energy storage related products, technology development and promotion of application

Hotline

18851514248

PRODUCT

Hotline

1885514248

Hydrogen injection proportional valve

Location:

  1. Home
  2. »
  3. Product
  4. »
  5. Hydrogen injection proportional valve

Hydrogen injection proportional valve

  • The amount of hydrogen spray is precisely controlled according to the current level
  • Low power consumption and small size
  • Electric valve opening and closing times life ≥ 100,000 times
  • Flexible design of customized mechanical interfaces

Hotline:

18851514248

  1. Overall structure:
  2. General Information:
    Weights: ~90 g
    Application range:~5KW electric reactor
  3. Product Key Features:
    • The amount of hydrogen spray is precisely controlled according to the current level
    • Low power consumption and small size
    • Electric valve opening and closing times life ≥ 100,000 times
    • Flexible design of customized mechanical interfaces
  4. Product size: product external dimensions length, width and height 48mm × 50.5mm × 120mm
  5. Product power consumption: product power <50w
  6. Installation Requirements:

    Mounting direction (shown): Vertical mounting
    HGI_MC Specific requirements at the fixed position:
    Before installation, make sure that the sealing surfaces of the interface parts of the air inlet and outlet of the product are free of scratches and damages; pay attention to the electrical connectors not to be bumped. When installing the fastening screws, make sure that the force of the screws is uniform, and recommend the screw type (M5).
  7. Working conditions:
    Working medium: H2;
    H2 cleanliness requirements, water content.
  8. Working conditions:
    • Working medium:Hydrogen (H2)
    • Normal working pressure:1.4~2 barA
    • Maximum working pressure Max. working pressure:3 barA
    • Leakage:max.10cc/h
    • Test conditions: Inlet pressure 4 bara, outlet pressure 1 bara, test medium: helium/hydrogen
    • Control valve working voltage:12V
    • Control method:PWM frequency ≥ 500 Hz
    • Maximum hydrogen injection Max. hydrogen injection flowrate :≥0.048g/s
    • Test conditions:
      Inlet pressure 1.2 bara, outlet pressure 1 bara, medium hydrogen, proportional valve flow ≥ 0.048 g/s at 1.8 A current.
    • Pick-up current:0.9A±0.1A
    • Resistive:2.37Ω±5%@20±3℃