- Overall structure:
- General Information:
Weights: ~90 g
Application range:~5KW electric reactor - Product Key Features:
- The amount of hydrogen spray is precisely controlled according to the current level
- Low power consumption and small size
- Electric valve opening and closing times life ≥ 100,000 times
- Flexible design of customized mechanical interfaces
- Product size: product external dimensions length, width and height 48mm × 50.5mm × 120mm
- Product power consumption: product power <50w
- Installation Requirements:
Mounting direction (shown): Vertical mounting
HGI_MC Specific requirements at the fixed position:
Before installation, make sure that the sealing surfaces of the interface parts of the air inlet and outlet of the product are free of scratches and damages; pay attention to the electrical connectors not to be bumped. When installing the fastening screws, make sure that the force of the screws is uniform, and recommend the screw type (M5). - Working conditions:
Working medium: H2;
H2 cleanliness requirements, water content. - Working conditions:
- Working medium:Hydrogen (H2)
- Normal working pressure:1.4~2 barA
- Maximum working pressure Max. working pressure:3 barA
- Leakage:max.10cc/h
- Test conditions: Inlet pressure 4 bara, outlet pressure 1 bara, test medium: helium/hydrogen
- Control valve working voltage:12V
- Control method:PWM frequency ≥ 500 Hz
- Maximum hydrogen injection Max. hydrogen injection flowrate :≥0.048g/s
- Test conditions:
Inlet pressure 1.2 bara, outlet pressure 1 bara, medium hydrogen, proportional valve flow ≥ 0.048 g/s at 1.8 A current. - Pick-up current:0.9A±0.1A
- Resistive:2.37Ω±5%@20±3℃
PRODUCT