1. Product size and interface:
2. Product introduction:
- Integrated Controller
- Active circulation of hydrogen/gas mixtures
- High speed, high flow, small size
- Customized CAN communication logic
- Flexible design of customized mechanical interfaces
3. Key parameters:
- Rated voltage: 24V/48V
- Rated power: 1kW
- Upper Limit Cyclic Flow Rate: Max. 1000L/min @ ΔP =0bar
- Outer size: 200mm x 130mm x 130mm
4. Product function connection:
5. Product functional parameters:
- Main Function
- Upper Limit Cyclic Flow Rate Max. recirculation flow rate: 1000L/min@?P=0mbar (mix-up gas)
- Maximum speed Max. speed: 20000rpm
- Leakage: max. 10cc/h
- Working Condition
- Normal Working Pressure: 1~3bara
- Media: H2, N2, H2O
- Media temperature: -35~85°C
- Interface
- Working voltage: 24V/48V
- Upper current limit Max. current: 45A/25A
- Rated Power: 1000W (Customizable small power example:500W)
- System Communication: CAN2.0
- Hydrogen Circulation Pump Pressurization ΔP – Flow Q curve: